N6
We offer our clients South Total Station N6 with handy EDM head. These are provided with complete application programs as well as extended internal memory of maximum 17000 Points. Further, these are available with automatic correction of input parameters. The specifications and distance measurement of South Total Station are detailed as follows:
Features:
- Convenient data management system.
- Superior waterproof and dust proof capabilities.
- Minimum reading 0.1 mm.
NTS-310RSeries
We offer our clients South Total Station N6 with handy EDM head. These are provided with complete application programs as well as extended internal memory of maximum 17000 Points. Further, these are available with automatic correction of input parameters. The specifications and distance measurement of South Total Station are detailed as follows:
Features:
- Convenient data management system.
- Superior waterproof and dust proof capabilities.
- Minimum reading 0.1 mm.
Description
Electric Wire Measurement
No worry about how to set up the prism, no need to use REM application. It is easy to get the data of electric wire.
Construction Measurement
Measure the corner and wall surface by yourself without setting the prism, the efficency is improved.
Tunnel Measurement
Prisms are not necessary.The measuring point-layout easier and more convenient.
Dam Measurement
You don’t have to take pains to go around and set prisms.The surveying work is easily finished.
House Measurement
Obtain the data directly, traditional steel ruler measurement is abandoned.
Cadastration Measurement
The corner, metop windows, electrical wire, telegraph pole, road, well all can be measured by one person without prisms.
N6 Distance Measurement (fine weather condition) Max. Range Reflectorless 300m 1 Prism 5.0km Angle Measurement Reflector: 2mm+2ppm; Reflectorless:5mm+3ppm Measurement Method Tracking mode:£0.5 s; Fine mode:£1.2 s Raster Disk Diameter Automatic correction by inputting parameter Minimum Reading Automatic correction by inputting parameter Accuracy 2″ 5″ Detection Method Absolute Encoding Telescope 79mm Image 1″/ 5″ selectable Length Horizontal: Dual Vertical: Dual Effective Aperture Erect Magnification 154mm Field of View Telescope: 45mm; Object Lens (50mm) Resolving Power Absolute Encoding Minimum Focussing Distance 79mm Auto Vertical Compensator 30X Type 1o30¡ Compensation Range 3″ Accuracy 1m Level Sensitivity Liquid-electric Detection Plate Vial ¡3¡ Circular Vial 1″ Optical Plummet 30″/ 2mm Image 8¡ / 2mm Magnification 30X Focusing Range 1o30¡ Others Display LCD, 6 Lines Data Port RS-232C , SD card Battery Voltage 6V (DC) Operating Time 8 hrs (small battery) ; 10 hrs (big battery) Charging Time 3 hrs Operating Temperature -20¡ ~ +45¡ Size & Weight 180¡150¡330mm, 5.2kg - Download Product Details